Geocel 2300

Designing and calculation. For optimal results, the gap between the surfaces must be a minimum of 4 times larger than potentially possible movement range of the connected surfaces. The sealant Geocel 2300 provides a stable connection from 6 х 6 mm to 12 х 12 mm (width х depth). Temperature of application. When performing the application, the temperature should range from -40°С to +60°С. Preparation. All surfaces should be defatted, cleaned of dust and dirt with a dry cloth or brush. If the temperature during application is lower than +5°С, the sealer must be warmed up for better adhesion. If the temperature during the application exceeds +60°С, the materials joined must be allowed to cool down.

Main characteristics

• joints will not crack
• joints have a high degree of flexibility (800%)
• joints are durable (more than 50 years)
• can be used in all weather conditions
• good compatibility with bitumen materials
• excellent adhesion to most building materials
• adheres well to wet surfaces
• joints are resistant to ultraviolet (UV) rays
• protects the surface from mould and fungus
• can be applied in several layers
• joints can be painted
• residues can be easily removed from tools and surface
• easy to use

APPLICATION

• majority of materials used in construction, such as bitumen, tar paper, tiles, concrete, bricks, glazed tiles, wood, glass, all metals, materials from polyvinyl chloride (PVC), etc..
• materials under load or subjected to vibration
• constructions subjected to structural movement
• in areas with high UV-requirements
• when coloured sealant is required
• as the connecting material, when materials cannot be screwed to each other, for example: glass and wood, glass and metal, glass and plastic, metal and metal etc. (for construction of facades, installation of windows, or greenhouses, where the connection should not only be flexible but also waterproof).

PRIMER COATING

Geocel 2300 may be used without primer coating on almost all surfaces, except for highly porous surfaces. It is recommended to apply primer coating on these materials.

APPLICATION RESTRICTIONS

• not applicable on surfaces exposed to friction
• extruded polystyrene foam
• acrylic windows
• in premises where food products are manufactured or stored

TYPE OF APPLICATION

Designing and calculation. For optimal results, the gap between the surfaces must be a minimum of 4 times larger than potentially possible movement range of the connected surfaces. The sealant provides a stable connection from 6 х 6 mm to 12 х 12 mm (width х depth).
Temperature of application. When performing the application, the temperature should range from -40°С to +60°С.
Preparation. All surfaces should be defatted, cleaned of dust and dirt with a dry cloth or brush. If the temperature during application is lower than +5°С, the sealer must be warmed up for better adhesion. If the temperature during the application exceeds +60°С, the materials joined must be allowed to cool down.
Application. Cut off the tip according to the joint width. Insert the tube in applicator. Press the sealant tightly into joints or cracks. Where necessary, smooth the joint with a scraper which has been drenched in soapy water for 5-10 minutes.
Painting. Latex or oil paints are recommended for painting. Joints can be painted no earlier than 24 hours after application. If the colour is inflexible – no earlier than 3 days after the application of the sealant.
Cleaning. Surplus sealant must be removed before it is hardened. White spirits is recommended for cleaning of tools and surfaces. Once hardened, the sealant can only be removed mechanically.

SAFETY MEASURES

Ensure good ventilation when working with the sealant. Avoid contact with skin and eyes. Upon contact with skin, wash your hands with soap and water. After eye contact, rinse them with water and consult a doctor. If swallowed, immediately consult a doctor.

STORAGE PERIOD

Properties of the product are guaranteed for 12 months from date of manufacture, if the product is stored in the original packaging in a dry and cool place (below +25°С).
Technical data
Viscosity of 800 centipoise
Elongation under tension 870%
Elongation under tension following increased exposure to UV for 500 h 1093%
Resistance to bursting 2.81 MPa
Resistance to bursting (with extension 900%) 6.21 MPa
Regeneration (following the extension of 800%) 100%
Shrinking while hardening 39%
Adhesion (with temperature + 23⁰C)
- Aluminium 3325 N/m
- Glass 2100 N/m
- Wood 2975 N/m
- Vinyl 2100 N/m
Hardening of the top layer 72h
Complete hardening of the joint (12.5 mm x 12.5 mm) 5 days
Application temperature from -40⁰C to +60⁰C
Thermal resistance from -40⁰C to +82⁰C
Volatile substances 37.5%
Requires no primer coating
Surfaces: suitable for brick, concrete, stone, all kinds of metal, glass, wood,
bitumen and vinyl materials. Used for sealing of gutters, roofs, windows, doors, metal
facades, cars.


CONSUMPTION OF SEALANT GEOCEL 2300

(1 tube, 305 ml)

Joint depth Joint width
6 mm 8 mm 10 mm 12 mm 15 mm
6 mm 8.0 m 6.0 m 5.0 m 4.0 m 3.2 m
8 mm 6.0 m 5.0 m 4.0 m 3.0 m 2.5 m
10 mm 5.0 m 4.0 m 3.0 m 2.0 m 1.4 m

PACKAGING

Tube (cartridge): 305 ml
Box: 24 tubes

 

Download

Specialists

Andris Lapa

+37129273143

brasta

Vjačeslavs Sivaho

+37126446117

brasta

Kaspars Krūmiņš

+37126114489

brasta

Where to buy